Hertel exophthalmometer

WitrynaThe .gov means it’s official. Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site. WitrynaExophthalmometry, the quantitative assessment of the position of the globe in the orbit, is a clinically useful measurement. The purpose of this study was to examine the …

[PDF] Proptosis—Correlation and Agreement between Hertel ...

Witryna13 lip 2024 · Generally, Hertel exophthalmometry correlates well with CT measurements. Subgroup analysis confirmed a superior quality of Hertel measurements in favour of … Witryna17 paź 2024 · Hertel exophthalmometer is used for precise exophthalmos measurements (e.g. Exophthalmic goiter). Sturdy construction for many years of use. Overall dimensions are 25 x 7 x 2 … cheaptickets naar barcelona https://olderogue.com

Exophthalmometer - an overview ScienceDirect Topics

WitrynaHertel exophthalmometer is a double ruler and mirror system, the footplates of which are placed on both lateral orbital margins simultaneously. The Hertel exophthalmometer was first described in 1905’ and has long been considered the standard for measuring the degree of prop- tosis.’ The Luedde exophthalmometer is Witryna24 wrz 2012 · Aim 1. In order to determine intrauser reliability of the Hertel exophthalmometer, patients will have 2 independent exams using the Hertel exophthalmometer on the same day performed by each of the same researcher (either DAC or HLP) in a blinded fashion. For each patient, we will independently measure … WitrynaInternational standardization of Hertel exophthalmometry is required in order to compare exophthalmometry data in the literature reliably. Reliability of exophthalmos … cyberview cs imagebox driver download

Hertel Exophthalmometer, Measurement Devices: Bernell …

Category:Hertel exophthalmometry: the most appropriate measuring …

Tags:Hertel exophthalmometer

Hertel exophthalmometer

Proptosis in Dysthyroid Ophthalmopathy: ACase Series of 10,931 …

WitrynaThe exophthalmometer is an instrument designed to measure the forward protrusion of the eye. This instrument provides a method of evaluating the recording the progression and regression of the prominence of an eye caused by disorders such as thyroid disease and tumors of the orbit. This instrument consists of a horizontal calibrated bar with ... Witryna12 sty 2024 · The Hertel exophthalmometer is used to determine the axial position of the eyes. The instrument is placed on the lateral orbital rim of each side, using as …

Hertel exophthalmometer

Did you know?

WitrynaObjective: To compare the reliability of orbital parameters calculated using 2-dimensional computed tomography (CT) and Hertel exophthalmometry when measuring … Witryna1 paź 1999 · The most widely used method is the Hertel exophthalmometer (Migliori and Gladstone, 1984;Dunsky, 1992), which measures the distance from the lateral orbital rim to the corneal surface in a ...

WitrynaHertel exophthalmometry was done for all cases by a single ophthalmologist using Hertel exophthalmometer (Oculus Inc., Wetzlar, Germany). Cycloplegia was obtained by alternatively instilling one drop of cyclopentolate 0.5% and one drop of tropicamide 0.5% at intervals of 5 minutes for a total of three drops per cycloplegic agent.

Witryna3 wrz 2024 · Table 3 Comparison of the Hertel exophthalmometer, computed tomography (CT), and 3D reconstruction software in patients who underwent orbital … WitrynaExophthalmometry is frequently used as a tool in the evaluation of proptosis. The purpose of this study was to compare the clinical usefulness of the newly developed …

WitrynaHertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy Javascript is currently disabled in your browser. …

Witryna1 gru 2003 · Hertel exophthalmometer is the most commonly used device, including in Sanglah General Hospital as tertiary care centrein Bali. The exophthalmometric measures tend to vary with age, sex, … cyberview cv-s101Witryna23 lut 2015 · A Hertel exophthalmometer was used by the same physician for the measurement of EV and inter-orbital distance (IOD). For the entire study population, the Hertel EVs ranged from 10 mm to 22 mm; the ... cheaptickets nederland contactWitryna17 lip 2015 · Although Hertel exophthalmometer and CT measurements are similar and strongly correlated, they do not agree well with each other in the presence of proptosis. ABSTRACT Aim: To determine the correlation and agreement between Hertel exophthalmometry and computed tomography (CT) of the orbits in measuring … cheap tickets ncaa basketballWitrynaNaugle exophthalmometer In case of acquired or congential asymmetry of the lateral orbital rims a Hertel exophthalmometer is misleading (see above). In these cases, a Naugle exophthalmometer is preferred since the referring structure is not the lateral orbital rim but the frontal and infraorbital structures. cyberview f1417Witryna1 lip 2009 · DOI: 10.1111/j.1475-1313.2008.00617.x Corpus ID: 23472070; Intra‐observer and inter‐observer variation of Hertel exophthalmometry @article{Lam2009IntraobserverAI, title={Intra‐observer and inter‐observer variation of Hertel exophthalmometry}, author={Andrew K. C. Lam and Chun-fai Lam and Wai-kit … cyberview dg-100sWitrynaZur Messung mit dem Exophthalmometer wird die Patientin aufgefordert, geradeaus zu schauen. Der Untersucher schiebt die beiden Rahmen so weit zueinander, bis deren Sporen an den temporalen Orbitarändern anliegen. Um sicherzustellen, dass kein Parallaxenfehler entsteht, sollte der rote Kontrollstrich in der Skalenausnehmung bei … cheap tickets nba gamesWitryna1 sty 2024 · The same Hertel exophthalmometer was used throughout the study. The Bland-Altman method was used to analyse the intra-observer and inter-observer agreement. The mean intra-observer and inter ... cheap tickets nederland